Oakrange Services
|
As required under the Electricity at Work Act 1989 Fixed Wire Testing is the testing of the circuits contained within the fabric of your building. This includes the socket outlets, lighting circuits and various others. The two main dangers associated with electricity are risk of shock and risk of...
|
Oakrange has provided a professional onsite Calibration service to the automotive industry since 1989. We have always prided ourselves on the high standard of calibration testing carried out, this ensures that our customers pass there dealer standard audits first time every...
|
Our Lighting Assessment and servicing ensures that no one is working in the dark! Assessments involve a full review of your lighting including a lighting levels LUX test to establish where lighting requires improvement.
Our team focuses on new technologies to ensure cost savings are introduced...
|
|
For over 20 years Oakrange has specialised in airfield equipment calibration, calibrating inclinometers, cable tensiometers and many more specialist airfield equipment across the UK.
Please contact us with your requirements and the technical team will be happy to chat through your tool list with...
|
Portable Appliance Testing (PAT) is an important part of any health & safety policy. The Electricity at Work Regulations place a legal responsibility on employers. This requires the implementation of a systematic and regular programme of testing.
Our Portable Appliance Testing service includes...
|
As well as general onsite calibration, Oakrange also carries out body shop calibration to PAS125:2007.
For further information please contact our service team who will go through your equipment list and arrange a calibration visit. As with all calibration visits, all certification will be...
|
|
Whilst maintaining our independence when carrying out Fixed Wire Testing we do provide a quotation outlining the electrical remedial work which is required. All electrical remedial work is carried out in line with BS7671, this includes all minor works and certification.
We are NICEIC contractors,...
|
Fire alarm certification, Smoke detector and Emergency Lighting testing is the testing of the safety critical warning systems contained within the fabric of your building. It is in the best interest of not only yourself and your employees, but also your insurance company and the general public that...
|
An important part of running your site is ensuring that you comply to fire regulations. After our trained assessor visits your site, a full report will detail the status of your whole site and where improvements and actions are required. A site map is also provided clearly illustrating where fire...
|
|
Oakrange can supply all your Health & Safety signage, equipment and consumables contact us for your requirements from emergency exit signage to fire escape signage all produced to the british standard.
|
Air tool HVAS servicing and repair.
Planned Preventative Maintenance (PPM) programme
On-site HAVS Assessments
Torque Calibration meeting UKAS standards
Engineers trained to ISO standards
A site maintenance report of all air tools HAVS test is provided on the customer portal...
|
Our in house torque wrench repair and calibration centre has been established for
over 20 years.
We specialise in the repair and calibration of all Norbar torque wrenches, and we carry most parts in stock.
We can carry out repairs on other makes if parts are available from the manufacturer.
We...
|
|
Our engineers are fully trained to carry out statutory examinations on your workshop lifting equipment onsite. This can be carried out at the same time, as your regular calibration visit and certification will be provided and available on the online customer portal.
|
Oakrange has produced a range of automotive test equipment, this includes the infamous ‘Bendix’ 3 Gauge Test Case, the associated Load Simulator and the Single Emergency Roadside Gauge.
Our products continue to be robust withstanding years of service in harsh workshop environment.
|
These are required under Health & Safety regulations to ensure that the noise levels with your workshop are at an acceptable level. A full survey is carried out demonstrating the noise levels from each piece of equipment and establishing a peak noise level operation. Previous clients have found...
|
|
This comprehensive service calibrates exhaust extraction units to ensure compliance to the air regulation standard. Full certification is provided and this service can be carried out at the same time as your regular calibration visit. Certification is available on the customer portal.
|
New to all customers for 2011!
We now supply a extensive range of tooling and garage equipment for all workshop needs. Not only will we compete on price but all tooling requiring a calibration certificate will be supplied with a current certificate prior to delivery. Check out our New Trade store...
|
Oakrange is one of only three companies in the UK able to carry out a full VAS 5051B test with an authorised Siemens supplied calibration unit.
A full 6-page report is provided with an immediate ‘pass or fail’ outcome. This is the minimum requirement as set out by the VAG quality...
|